MODEL |
PM-WCC-100AM-1248
|
ELECTRICAL |
Input Voltage Range (no
damage) |
0 ~ 220 VAC
|
Operating Input
Voltage Range from PMG
(Permanent Magnet Generator) |
20 ~ 220 VAC
0 ~ 600 Hz
|
Optimal Range: 20 ~ 180 VAC
|
System voltage ratings |
12, 24, 36, 48 VDC
|
Current ratings-Battery
Charge Control |
100A
|
Max. Current in the Brake
Resistor |
100A
Diversion load
|
DC Output
Voltage Range |
16 ~ 240 VDC Operating
|
240 VDC Maximum
|
Automatic Brake Function |
5 Level:
200, 210, 220, 230, 240 VDC
(Adjustable)
Can
be customized for the wind turbines
|
Maximum
Wind Turbine Capacity |
Charging 48 VDC Batteries
|
6.0KW
|
Charging 36 VDC Batteries
|
4.5KW
|
Charging 24 VDC Batteries
|
3.0KW
|
Charging 12 VDC Batteries
|
1.5KW
|
Charge Regulation Modes |
Bulk, Absorption, Float, Auto/ Manual
Equalization
|
Battery Temperature
Compensation |
5.0 mV per ¡ÆC , per 2 volt cell
|
DC to DC
Conversion Capability |
12V Battery: 16~240VDC
|
24V Battery: 32~240VDC
|
36V Battery: 48~240VDC
|
48V Battery: 64~240VDC
|
Display Status |
Built-in 2-line, 20-character LCD with
backlight
LCD status screen displays input voltage
and
current, output voltage and current,
charge-mode,
Battery SOC
|
Data Logging |
Logs energy
harvested for 90 days, LCD displays WH, KWH,
AH |
Energy Monitor |
LCD shows SOC,
AH, WH, and present charge or discharge
current. A 50mV/ 500Amp shunt is required to
use |
Auxiliary Relays |
Two independent
relays with from A (SPST) contacts for
control of external devices. Contact rating
is 3 Amps, 50VDC |
Operation Temperature |
Full Power
Output to +50 ¡ÆC ambient |
Standby Power |
< 2 Watts
|
Relative Humidity |
0 ~ 100% condensing
|
MECHANICAL |
Dimensions (mm) [H x W x L] |
401 x 258 x 183
|
Weight |
8.3 kg
|
Optional Diversion Load |
¡¡ |
Specifications
subject to change without notice |